T-Rex Exit Detector
|
| The T-Rex is a sophisticated and cost effective request to exit (REX) device for all access control applications and an alternative to installing an exit button. The T-Rex allows Hands-Free exit as it detects the user as they approach the exit and automatically unlocks or shunts the door. |
 |
Applications include:
- Hands free - no buttons to push.
- Integrated 90dB sounder that is activated when the door is left open or forced from the outside.
- Zone of detection easily adjustable from 90cto 5°c to ensure pinpoint accuracy for detection.
- Digital Signal Processing (DSP), coupled with Infrared detection recognises fast human movement towards the door i.e. a hand reaching for the push plate. This prevents the door being able to be opened by sliding objects under the outside of the door.
- Available with Tamper, Timer, Piezo.
|
|
| Ordering Information |
| Part Number |
Description |
| TREX-LT |
T-REX Exit detector with tamper and timer. |
| TREX-XL |
T-REX Exit detector with tamper piezo and timer. |
|
Exit Buttons
|
 |
 |
 |
 |
| EB1 |
EB2 |
EB3 |
EB4 |
 |
 |
 |
 |
| EB5 |
EB6 |
BBU |
BGU-S |
|
| Ordering Information |
| Part Number |
Description |
| BBU |
12VDC 7.2Ah Battery. |
|
| Ordering Information |
| Part Number |
Description |
| BGU |
Break glass unit. |
| BGU-DP |
Double pole break glass unit. |
|
| Ordering Information |
| Part Number |
Description |
| EB1 |
White plastic exit button, low traffic, back box mount. |
| EB2 |
Flush stainless steel exit button, back box mount. |
| EB3 |
Plastic low traffic exit button, narrow style, suitable for door frame mount. |
| EB4 |
Flush stainless steel exit button, narrow style, suitable for door frame mount. |
| EB5 |
Stainless steel exit buttonwith large green dome, square, flush mount (order surface kit seprerately). |
| EB6 |
Touch sensitive green exit button, square, flush mount (order surface kit seperately). |
|
Slimline Electro Magnetic Locks
|
 |
The Slimline is a quality electro magnetic lock that has a range of features
to suit most applications, including double doors.
- Monitored and unmonitored models are available.
- 12V current draw: Single magnet = 600mA
Double magnet = 1.2A
- 24V current draw: Single magnet = 300mA
Double magnet = 600mA
- Dimensions: Magnet L227 x W36 x D36 Plate L185 x W36 x D36
- Holding force: 450 - 550LBS per door.
|
|
| Ordering Information |
| Part Number |
Description |
| ML0012 |
12/24 VDC Slimline magnet, unmonitored. |
| ML0022 |
12/24VDC Slimline magnet, monitored. |
| ML0052 |
12/24VDC Slimline double magnet, unmonitored. |
| ML0062 |
12/24VDC Slimline double magnet, monitored. |
| LH0001 |
L Bracket (for outward opening doors). |
| LH0002 |
Z & L Brackets (F section). |
|
Standard Electro Magnetic Locks
|
 |
The standard electro magnetic lock is an efficient, low power device and
suits a variety of access control requirements.
- Available in monitored and unmonitored versions.
- Finished in Satin anodised aluminium.
- 12V current draw: 600mA
- 24V current draw: 300mA
- Dimensions: L268 x W30 x D33
- Holding force: 1100 - 1200LBS per door.
|
|
| Ordering Information |
| Part Number |
Description |
| ML0072 |
112/24VDC Standard magnet, unmonitored. |
| ML0080 |
12/24VDC Standard magnet, monitored. |
| LH0003 |
L Bracket (for outward opening doors). |
| HM0030 |
Z & L Bracket for inward opening doors. |
| DML073 |
12/24VDC standard double magnet - unmonitored. |
| DML074 |
12/24VDC standard double magnet - monitored. |
|
External Electro Magnetic Locks
|
 |
An exterior quality electro magnetic lock designed to suit most external
applications.
- Low energy consumption.
- No moving parts to wear out.
- Reed switch monitoring.
- Power supply 12VDC/24VDC conduit adaptor.
- Holding force: 1100 - 1200LBS per door.
|
|
| Ordering Information |
| Part Number |
Description |
| ML0100 |
12/24VDC Face fix external magnet, monitored. |
|
Shear Electro Magnetic Locks
|
 |
The Shear electro magnetic lock is designed to be morticed into the door and frame and can be fitted horizontally or vertically.
- 12V current draw. Kicks in 8 seconds at 1.8A holding 450mA
- 24V current draw. Kicks in 8 seconds at 900mA holding 225mA
- Door or lock status monitoring.
- Single or double action door operation.
- Adjustable ‘shear' pin.
- Holding force = 3000LBS (in shear).
|
|
| Ordering Information |
| Part Number |
Description |
| ASL-705-30 |
12/24VDC GS705 shear magnet, monitored. |
|
Electric Door Strikes
|
 |
An electronic release is a cost effective, extremely reliable access controllocking device, generally installed in low-traffic applications.
- Dual voltage 12V or 24C, AC or DC
- Cost effective solution.
- GAER current draw: 250mA
- ARU current draw: 150mA
|
|
| Ordering Information |
| Part Number |
Description |
| Gear |
Fail secure release kit. |
| Gear-1 |
Fail safe release kit. |
| ARU |
ANSI Reversible release, heavy duty. |
| ARU-M |
ANSI Reversible release - Monitored, heavy duty. |
|
|
|
|
| Copyright © 2006